test subject: jh audio alpha feedback, filter center freq=9.4Hz, bw=2Hz feedback threshold=30uVp-p CH0: Cz-Au2 DRL: on lower right leg recorded data can be viewed with bwview (http://uazu.net/bwview/) bwview raw/256:s sessionname.pcm sitting, eyes closed ON-OFF-ON training marker: 3-times clenching jaw (giving an about 200uVp-p EMG signal) timeindex (seconds) 000: 14Hz squarewave calibration signal 250uVp-p 064: marker, start alpha feedback 077: alpha amplitude increases 260: marker, start OFF phase 327: marker, end OFF phase, start ON phase 344: alpha amplitude increases 500: marker, end ON phase, start OFF phase 574: marker, end OFF phase, start ON phase 739: marker, end ON phase, next phase is the attempt to observe ideoretinal lights without disturbing alpha 937: end